Implant-TIC records which parts are documented for which implant system, and on what evidence. This page sets out the catalogue’s rules in the order a reader needs them.
What Implant-TIC is, and is not
Implant-TIC is a technical catalogue and compatibility research aid. It lists dental implant systems and the restorative parts, screws, drivers, torque wrenches and surgical kits documented for them.
The app runs as an invite-only pilot, starting in the United Kingdom.
It is
- A catalogue that shows the source of each match.
- A way to see where documentation is missing.
It is not
- A shop. Implant-TIC does not sell, stock or ship parts.
- Complete. It does not cover every implant system, and coverage differs from one system to the next.
- An identification. Identify an Implant shows possible matches, not an identification.
- Clinical advice. Confirm every selection against the current manufacturer instructions for use and the specific clinical case.
Where the data comes from
A compatibility record is added only from documentation. Each record carries a link to its source. Sources are taken in this order.
- Source AImplant-maker documentation.
- Source BComponent-maker documentation.
- Source CA secondary source, such as a device registry or a distributor’s catalogue.
What is never used as evidence
A fit is never inferred. Two products that look alike, or share a name or a size, are not recorded as compatible for that reason alone. The following do not count as evidence:
- A shared connection label
- A shared diameter
- A platform nickname
- A screw size
- A drive size
- Colour
- Geometry
- Membership of the same corporate group
The five evidence states
Every compatibility record shows one of five states, with the same colours as in the app. The labels say what the evidence is, from strongest to weakest. None of them means that Implant-TIC has tested the fit. Missing data never becomes a positive claim.
In the catalogue today, 526 of 4,013 records are unverified, and each one is labelled as such. No record has been tested by Implant-TIC.
- Manufacturer documentedA manufacturer’s document lists this part for this implant system and platform. The copy cited may be hosted by someone else, such as a distributor; the source link says where.
- Supplier documentedA third-party part whose maker states that it fits. The implant manufacturer does not document it, and may not support its use.
- Secondary sourceListed in a source that is neither the implant manufacturer’s nor the part maker’s own document, such as a device registry, a distributor’s catalogue or a reproduction of a catalogue. Not physically tested. Weaker than manufacturer or supplier documentation.
- Unverified — requires reviewFound, but the source does not clearly state this fit, or the record could not be checked. It is not shown as a fit in 3D. Confirm it with the manufacturer.
- Documented incompatibleA source states that these parts do not fit together.

Original, third-party and “Maker claim”
Original parts and third-party parts are labelled as such wherever they appear, in lists, filters and tags.
Sometimes an implant maker states that its parts fit another system. That statement is quoted, sourced, matched to the platform and labelled “Maker claim”.
Screws and drivers
A screw is linked to a driver only under these rules.
- A document must pair the two products. The record keeps the sentence that does so, and its link.
- “Universal” is used only when the maker says so and names the scope.
- A screw with an angulated channel is never paired with a standard driver.
- One implant maker’s screw is never mapped onto another maker’s implant line.
Platform not stated, and abutment-level parts
If an implant’s platform is not stated, it gets no parts. Nothing is guessed from its name or diameter.
Parts that mount on an abutment are linked only through the abutment they mount on, never directly to the implant.
When sources disagree
If a source contradicts itself or another source, the record is marked unverified and set aside for review. Data with higher confidence is never overwritten by data with lower confidence.
3D models
The 3D models are generated by Implant-TIC. They are not manufacturer CAD files. Parts are assembled in the viewer only where a fit is documented. Documented dimensions are used where they exist, and otherwise the model is illustrative.
Change history
Each published change to the catalogue is recorded, and the app shows its change history.
Gaps stay visible
When a value is unknown, the catalogue says “Not documented”. It does not estimate, and it does not borrow the value from a similar product.
How complete the data is
The app’s Evidence and Verification section shows what the data holds and how complete it is. No manufacturer is marked Complete.